PVC Pipe Standards in Saudi Arabia

PVC and uPVC pipe supplied in Saudi Arabia is governed by four standard families: Saudi Standards (SAS and SASO), American (ASTM), German (DIN) and North American electrical (NEMA). 4B Factory manufactures to these specifications at its Al-Kharj plant and supplies the compliance documentation required for municipal, government and contractor approval.

PVC pipe manufactured to SAS, SASO and ASTM standards at the 4B Factory plant in Al-Kharj
SAS & SASO Saudi
Standards
SAS 254 / 255Duct & Conduit
SAS 1395 / 1396Sewer & Drain
ASTM D 1785Schedule 40 / 80
DIN 8061 / 8062Metric Rigid PVC
NEMA TC 2EPC 80-PVC
Why Standards Decide the Order

Specification First, Price Second

On a Saudi project the standard is usually written into the bill of quantities before a supplier is chosen. A consultant who has specified SAS 1395 for buried sewerage, or NEMA TC 2 for underground electrical duct, is not comparing pipe on price until the submitted product matches the clause. Pipe that cannot evidence the specification does not reach the pricing stage at all.

That is why this page sets out what each standard actually governs, which product line it applies to at 4B Factory, and what documentation accompanies an order. For the SASO route specifically, see the dedicated page on SASO approved PVC pipes.

uPVC watermain pressure pipe in Class 4 and Class 5 manufactured to Saudi Standards
Reference Table

PVC Pipe Standards Cross Reference

What each standard governs, the body that issues it, and the 4B Factory product line it applies to. Use this to match a specification clause to a product before requesting a quotation.

StandardIssued byWhat it governsApplies to
SAS 254 & SAS 255SASOuPVC conduit and duct pipe for telephone and power cable protectionuPVC Duct Pipes, 20 to 63 mm, dark grey
SAS 1395 & SAS 1396SASOuPVC pipe and fittings for buried sewerage and drainage systemsSewer & Drain Pipes, Class 2 to 4, 110 to 710 mm
SASO ISO 1452SASO with ISOuPVC pressure piping systems for water supply, including potable waterWatermain Pressure Pipes, Class 4 & 5, 50 to 315 mm
ASTM D 1785ASTM InternationalRigid PVC pipe in Schedule 40, 80 and 120, dimensions and pressure ratingPVC ASTM Standard Pipes, half inch to 8 inch
ASTM D 2241ASTM InternationalPVC pressure pipe classified by standard dimension ratio (SDR)PVC ASTM Standard Pipes, SDR series
ASTM D 1784ASTM InternationalCell classification of the rigid PVC compound itself, for example 12454Compound specification across all lines
DIN 8061 & DIN 8062DINGeneral quality requirements and metric dimensions for rigid PVC pipeMetric pipe where a DIN clause is specified
NEMA TC 2NEMARigid PVC electrical conduit in EPC 40 and EPC 80 wall thicknessesPVC Conduit & Duct, half inch to 6 inch

Standards are revised periodically. Always confirm the revision year cited in your project specification before submitting material for approval. The current Saudi technical regulation covering pipes used in water, electricity and gas networks is published by SASO.

Classes & Ratings

Pressure Class and Wall Designation Reference

Class means different things in different standard families, which is a common source of specification error. Pressure class describes a pressure rating. Sewer class describes ring stiffness on a gravity line, not pressure.

DesignationStandard familyWhat it meansTypical specification
Class 4Saudi pressure pipeRated to 10 Bar working pressureDistribution mains and utility water
Class 5Saudi pressure pipeRated to 16 Bar working pressure, thicker wallTrunk mains and higher head duty
Class 2, 3, 4SAS 1395 / 1396 sewerRing stiffness on a gravity line, not a pressure ratingBuried sewerage and storm drainage
Schedule 40ASTM D 1785Wall thickness series; pressure rating falls as diameter risesGeneral pressure and light process duty
Schedule 80ASTM D 1785Thicker wall than Schedule 40 at the same nominal sizeIndustrial, chemical and process service
SDR seriesASTM D 2241Constant wall to diameter ratio, so rating holds across sizesIrrigation and pressure distribution
EPC 80-PVCNEMA TC 2Heavy wall rigid non-metallic electrical conduitUnderground power and telecom cable

Full size, class and pressure breakdowns sit on each product page. For indicative cost impact of moving between classes, see the PVC pipe price guide for Saudi Arabia.

Standard to Product

Find the Product Behind the Clause

Every category below is manufactured in Al-Kharj and supplied Kingdom wide. Open any product for its full size, class and standard detail.

uPVC duct pipes manufactured to SAS 254 and SAS 255 by 4B Factory

uPVC Duct Pipes

SAS 254 / 255. Sizes 20 to 63 mm, dark grey, 6 m lengths.

More Information
uPVC sewer and drain pipes manufactured to SAS 1395 and SAS 1396 by 4B Factory

Sewer & Drain Pipes

SAS 1395 / 1396. Class 2 to 4, 110 to 710 mm, integral joints.

More Information
uPVC watermain pressure pipes in Class 4 and Class 5 by 4B Factory

Watermain Pressure Pipes

Loc-Ring integral socket. Class 4 & 5, 50 to 315 mm, blue.

More Information
PVC ASTM standard pipes to ASTM D 1785 and D 2241 by 4B Factory

PVC ASTM Standard Pipes

ASTM D 1785 / D 2241. Schedule 40, 80, 120 and SDR.

More Information
PVC conduit and duct pipes to NEMA TC 2 EPC 80-PVC by 4B Factory

PVC Conduit & Duct

NEMA TC 2 EPC 80-PVC. Half inch to 6 inch nominal.

More Information
Perforated uPVC pipes for drainage and dewatering by 4B Factory

Perforated uPVC Pipes

Straight and staggered perforation, 75 to 500 mm, custom patterns.

More Information
Customised PVC fittings made to project specification by 4B Factory

Customized Fittings

Flanged sockets, spigots, repair and register couplings to order.

More Information
PVC fabricated products including long bends rated 6 to 16 Bar by 4B Factory

PVC Fabricated Products

Long bends, repair and register couplings, 6 to 16 Bar.

More Information
Where Standards Apply

Standards by Project Type

Municipal Water Networks

Pressure pipe specified by class, with SASO documentation required at approval stage.

Sewerage & Drainage

SAS 1395 and 1396 govern buried gravity lines, with class set by ring stiffness.

Electrical & Telecom Networks

SAS 254 and 255 for uPVC duct, NEMA TC 2 where a North American clause is written in.

Industrial & Process Plant

ASTM D 1785 Schedule 40 and 80, with compound cell class under ASTM D 1784.

What You Receive

Compliance Support from the Manufacturer

Documentation With Every Order

Standards documentation supplied for contractor, consultant and municipal approval.

Multi Standard Production

Saudi, American and German specifications produced on the same Al-Kharj lines.

Specification Matching

Send the clause from your bill of quantities and we confirm the matching product line.

Saudi Manufacturing

Produced in Al-Kharj Industrial District 27, not imported and re-labelled.

Factory-Direct Supply

Buy from the manufacturer with no distributor margin on project quantities.

Technical Team Response

Engineering support on class selection, jointing and submittal preparation.

Further reading on how the compliance route works in practice sits on the SASO approved PVC pipes page and across the 4B Factory technical blog.

Send Us the Specification Clause

Send the standard, class, diameter and quantity from your bill of quantities and the technical team will confirm the matching product line, the documentation supplied, and factory-direct pricing for delivery anywhere in Saudi Arabia.

FAQ

Frequently Asked Questions

Four families apply. Saudi Standards (SAS, issued by SASO) cover duct pipe under SAS 254 and 255 and sewer pipe under SAS 1395 and 1396. ASTM covers Schedule and SDR pressure pipe under D 1785 and D 2241. DIN 8061 and 8062 cover metric rigid PVC. NEMA TC 2 covers rigid electrical conduit.

SASO is the Saudi Standards, Metrology and Quality Organization, the body that issues and enforces standards. SAS is the designation carried by the standards themselves, such as SAS 1395. A specification will normally cite the SAS number, while approval documentation refers to SASO as the issuing authority.

They cover uPVC pipe and fittings for buried sewerage and drainage. Pipe supplied to these standards is produced in Class 2, 3 and 4 across 110 to 710 mm. The class here describes ring stiffness on a gravity line rather than a pressure rating, which is a frequent point of confusion at specification stage.

SAS 254 and SAS 255 apply to uPVC conduit and duct pipe for telephone and power cable protection, supplied in 20 to 63 mm. Where a project specification is written to a North American clause instead, NEMA TC 2 EPC 80-PVC applies, supplied from half inch to 6 inch.

D 1785 classifies rigid PVC pipe by Schedule, so wall thickness is fixed per nominal size and the pressure rating falls as diameter rises. D 2241 classifies pipe by standard dimension ratio, holding wall to diameter constant so the pressure rating stays the same across sizes within one SDR series.

It depends entirely on what the project specification cites. Many Saudi municipal and utility specifications call up SAS numbers, while industrial, process and international contractor projects frequently specify ASTM or DIN. 4B Factory produces to all three families, so the answer is set by the clause rather than by the supplier.

Yes. Standards documentation is supplied with orders for contractor, consultant and municipal approval. Send the specification clause, diameter, class and quantity to the technical team and the matching product line and accompanying documentation will be confirmed with the quotation.

4B Factory (Four Brothers Industrial Co.)

Match Your Specification to Saudi-Made Pipe

Manufactured in Al-Kharj Industrial District 27 to Saudi, American and German standards, and delivered across the Kingdom. Call, WhatsApp, or email info@4bfactory.com.